Product features
● Built in high subdivision
● Automatic parameter setting function when power on
● Optical isolation differential signal input
● Pulse response frequency can reach up to 500KHz (Factory default 160KHz)
● Pulse mode/IO mode can be switched freely through dialing
Electrical characteristics
Instructions |
Min |
Typical |
Max |
Unit |
Continuous output current |
0.1 |
- |
3.0 |
A |
Power supply voltage (DC) |
12 |
24 |
50 |
Vdc |
Logic input current |
6 |
10 |
16 |
mA |
Logic input voltage |
5 |
5 |
24 |
Vdc |
Minimum pulse width of input signal |
1.5 |
- |
- |
us |
Step pulse frequency |
0 |
- |
160 |
KHz |
insulation resistance |
500 |
- |
- |
MΩ |
Current setting
Peak |
RMS |
SW1 |
SW2 |
SW3 |
SW4 |
Default[0.1A] |
on |
on |
on |
on |
0.28A |
0.2A |
off |
on |
on |
on |
0.42A |
0.3A |
on |
off |
on |
on |
0.60A |
0.5A |
off |
off |
on |
on |
0.84A |
0.6A |
on |
on |
off |
on |
0.98A |
0.7A |
off |
on |
off |
on |
1.12A |
0.8A |
on |
off |
off |
on |
1.40A |
1.0A |
off |
off |
off |
on |
1.68A |
1.2A |
on |
on |
on |
off |
1.82A |
1.3A |
off |
on |
on |
off |
2.10A |
1.5A |
on |
off |
on |
off |
2.24A |
1.6A |
off |
off |
on |
off |
2.38A |
1.7A |
on |
on |
off |
off |
2.52A |
1.8A |
off |
on |
off |
off |
2.80A |
2.0A |
on |
off |
off |
off |
3.00A |
2.2A |
off |
off |
off |
off |
Function settings
[SW9] Selection of upper and lower edges;
[SW10] Response time;
[SW11] [SW12] Pulse mode/IO mode selection
Mode sel |
SW11 |
SW12 |
IO internal spontaneous pulse 1 |
on |
on |
IO self check |
on |
off |
Double pulse |
off |
on |
Pulse+direction |
off |
off |
Subdivision setting/IO internal spontaneous pulse setting
Pulse/rev |
SW5 |
SW6 |
SW7 |
SW8 |
IO/RPM |
Default[200] |
on |
on |
on |
on |
10 |
400 |
off |
on |
on |
on |
20 |
800 |
on |
off |
on |
on |
30 |
1600 |
off |
off |
on |
on |
40 |
3200 |
on |
on |
off |
on |
50 |
3600 |
off |
on |
off |
on |
60 |
6400 |
on |
off |
off |
on |
80 |
12800 |
off |
off |
off |
on |
100 |
1000 |
on |
on |
on |
off |
120 |
2000 |
off |
on |
on |
off |
150 |
4000 |
on |
off |
on |
off |
200 |
5000 |
off |
off |
on |
off |
250 |
7200 |
on |
on |
off |
off |
300 |
8000 |
off |
on |
off |
off |
350 |
10000 |
on |
off |
off |
off |
450 |
20000 |
off |
off |
off |
off |
600 |
Dimension drawing(mm)
It is recommended to use side installation for better heat dissipation effect.