Product features
● Built in high subdivision
● Automatic parameter setting function when power on
● Optical isolation differential signal input
● Pulse response frequency can reach up to 500KHz (Factory default 200KHz)
● Pulse mode/IO mode can be switched freely through dialin
Electrical characteristics
Instructions |
Min |
Typical |
Max |
Unit |
Continuous output current |
2.0 |
- |
8.4 |
A |
Power supply voltage (DC/AC) |
30/24 |
130/110 |
150/120 |
Vdc/Vac |
Logic input current |
6 |
10 |
16 |
mA |
Logic input voltage |
5 |
5 |
24 |
Vdc |
Minimum pulse width of input signal |
0 |
- |
200 |
KHz |
Step pulse frequency |
1.5 |
- |
- |
US |
insulation resistance |
100 |
- |
- |
MΩ |
Current setting
Peak |
RMS |
SW1 |
SW2 |
SW3 |
Default[2.0A] |
off |
off |
off |
3.60A |
2.57A |
on |
off |
off |
4.40A |
3.14A |
off |
on |
off |
5.20A |
3.71A |
on |
on |
off |
6.00A |
4.28A |
off |
off |
on |
6.80A |
4.86A |
on |
off |
on |
7.60A |
5.43A |
off |
on |
on |
8.40A |
6.00A |
on |
on |
on |
[SW4] is a half flow function:
When SW4=off, it is set to half flow;
When SW4=on, the current is in static state- full current locking axis
Function settings
[SW9] Selection of upper and lower edges;
[SW10] Response time;
[SW11] [SW12] Pulse mode/IO mode selection
Mode sel |
SW11 |
SW12 |
IO internal spontaneous pulse 1 |
on |
on |
IO self check |
on |
off |
Double pulse |
off |
on |
Pulse+direction |
off |
off |
Subdivision setting/IO internal spontaneous pulse setting
Pulse/rev |
SW5 |
SW6 |
SW7 |
SW8 |
IO/RPM |
Default[400] |
on |
on |
on |
on |
10 |
800 |
off |
on |
on |
on |
20 |
1600 |
on |
off |
on |
on |
30 |
3200 |
off |
off |
on |
on |
40 |
6400 |
on |
on |
off |
on |
50 |
12800 |
off |
on |
off |
on |
60 |
25600 |
on |
off |
off |
on |
80 |
51200 |
off |
off |
off |
on |
100 |
1000 |
on |
on |
on |
off |
120 |
2000 |
off |
on |
on |
off |
150 |
4000 |
on |
off |
on |
off |
200 |
5000 |
off |
off |
on |
off |
250 |
8000 |
on |
on |
off |
off |
300 |
10000 |
off |
on |
off |
off |
350 |
20000 |
on |
off |
off |
off |
450 |
40000 |
off |
off |
off |
off |
600 |
Dimension drawing(mm)
It is recommended to use side installation for better heat dissipation effect.